Introduction

Principle & Structure

The thermal gas mass flowmeter is designed based on the principle of thermal diffusion. The instrument uses the constant temperature difference method to accurately measure the gas. It has the advantages of small size, high degree of digitization, convenient installation and accurate measurement.

The sensor part is composed of two reference-grade platinum resistance temperature sensors. When the instrument is working, one sensor continuously measures the medium temperature T1; the other sensor is self-heating to be higher than the medium temperature T2, which is used to sense the fluid flow rate, which is called velocity sensor. The temperature ΔT=T2-T1, T2>T1, when there is fluid flowing, the temperature of T2 drops because the gas molecules collide with the sensor and take away the heat of T2. To keep ΔT unchanged, it is necessary to increase the temperature of T2. With the power supply current, the gas flows faster, and the more heat is taken away. There is a fixed function relationship between the gas flow rate and the added heat.

technical parameter

Nominal diameter (mm):Pipeline: DN10~DN125
Plug-in type: DN100~DN2000 (customized for special pipes)
Measuring range:See detailed flow parameter table
Accuracy:Pipeline: ±1.0%FS, ±2%FS
Plug-in: ±1.5%FS, ±2.5%FS
Repeatability:±0.25%FS
Response time:2 seconds to reach 63% of final value (a time constant)
Sensitivity:< 0.05 m/s
Power supply:24VDC,AC220V
Total power consumption:less than 20W
output signal:Current output photoelectric isolation 4~20mA: 0~500KΩ
RS485 (Modbus protocol), HART
Alarm signal: 1-2 relay normally open contact signal
24VDC,10A;220VAC,10A
Display content:Mass flow, standard volume flow
Instantaneous flow, cumulative flow, medium flow rate, cumulative running time
Flow percentage (instantaneous flow 6 digits, cumulative flow 10 digits)
Instantaneous flow unit:Nm3/h,Nm3/min,
L/h,L/min,t/h,t/min,
kg/min,kg/h,
Record store query:day record, month record, year record
Instrument shell material:Cast Aluminum & Glass
Sensor Material:Stainless steel 1.4301(304)
Stainless steel 1.4435 (316L)
Applicable pipeline material:Carbon steel stainless steel plastic etc.
Protection class:IP65
Explosion-proof grade:ExdⅡCT2~6 (certification in progress)
Working pressure:Pipeline: ≤40bar
Plug-in: ≤25bar
Connection method:Flange and threaded connections can be used between the flowmeter and the piping
Required straight pipe length:Upstream≥5DN, downstream≥3DN
Flow direction:Positive, negative, net flow
Implementation standard:DIN EN 1092-1-2002
Standard of the place of use for sales (Order remarks)
LVD 2006/95/EC&EMC 2004/108/EC
EN 61326-1::2006 Emission Standard (BS EN50081-1)
EN 61326-1::2006 Immunity Standard (BS EN50082-1)
EN 61010-1:2001 Equipment Safety Requirements: General Requirements
Fluid temperature:-40~+120℃, -40~+220℃
Ambient temperature:-10~+55℃
environment humidity:<90%rh (non-condensing)

Selection table

FGM10-Thermal gas mass flow meter (on-line pipeline type)
FGM20-Thermal gas mass flowmeter (sleeve thread insertion type, with external thread)
FGM30-Thermal gas mass flowmeter (on-line installation plug-in, low-pressure online plug-in, including ball valve and packing gland)
FGM40-Thermal Gas Mass Flow Meter (Flange Insertion Type)

structure type

local header

Remote header with cable length in parentheses

Nominal diameter

DN10~DN125 (online pipeline type)

DN100~DN500 (small diameter plug-in)

DN600~DN2000 (large diameter plug-in)

Power supply

24VDC±10% DC power supply

100~240VAC AC power supply

output signal

No signal output

4~20mA current signal

HART protocol type

display form

no display

Local digital jump display mass flow (instantaneous, cumulative, flow rate, flow percentage)

Accuracy class

±1.5%FS

±1.5%FS

±2.0%FS

Conventional Accuracy (or Fine Calibration Interval)

(optional accessories)

no accessories

gas rectifier
The complete data of this selection table, please contact the sales staff or email to sales@kewill-auto.cn for complete samples.
Prev :No
Next:FGM Gas Mass Flowmeter (Pipeline)
主站蜘蛛池模板: 久久99久久精品久久久久久 | 青青草91久久国产频道 | 看毛片软件 | 欧美一区二区高清 | 国产成人aa免费视频 | 热久久视久久精品18国产 | 97视频精品全国在线观看 | 黄色网站在线观看视频 | 欧美日韩亚洲区久久综合 | 精品综合久久久久久97超人该 | aa黄色片| 九九免费视频 | 免费高清影视 | 婷丁六月 | 久久久www成人免费精品 | 精品视频在线观看 | 好姐妹1韩国版 | 久草综合网| 日韩视频免费 | 欧美精品一区二区三区免费观看 | 五月花精品视频在线观看 | 丝袜精品 欧美 亚洲 自拍 | 日韩在线视频免费不卡一区 | 色青五月天 | 久久这里只有精品久久 | 国产在线视频自拍 | 四虎884| 国产黄色小视频在线观看 | 免费看高视频hh网站免费 | 久久久久国产精品免费看 | 国产欧美日韩在线观看 | 免费羞羞网站视频 | 国产羞羞视频在线观看 | 精品伊人久久久久7777人 | 奇米影视第四影院在线观看 | 97色在线视频 | 99久久国产综合精品网成人影院 | 国产高清一级毛片在线不卡 | 国产亚洲人成网站在线观看 | 国产福利一区二区精品免费 | 国产精品久久永久免费 |